Important Safety Information

Indication

NEXOBRID® (anacaulase-bcdb) is indicated for eschar removal in adults and pediatric patients with deep partial thickness (DPT) and/or full thickness (FT) thermal burns.

Limitations of Use

The safety and effectiveness of NEXOBRID have not been established for treatment of:

  • Chemical or electrical burns
  • Burns on the face, perineum, or genitalia
  • Burns on the feet of patients with diabetes mellitus or on the feet of patients with occlusive vascular disease
  • Circumferential burns
  • Burns in patients with significant cardiopulmonary disease, including inhalation injury

NEXOBRID is not recommended for:

  • Wounds contaminated with radioactive and other hazardous substances to avoid unforeseeable reactions with the product and an increased risk of spreading the noxious substance
  • Treatment of burn wounds where medical devices (e.g., implants, pacemakers, shunts) or vital structures (e.g., large vessels) could become exposed during eschar removal

Important Safety Information

Contraindications

NEXOBRID is contraindicated in patients with: known hypersensitivity to anacaulase-bcdb, bromelain, pineapples, or to any other components; known hypersensitivity to papayas or papain because of the risk of cross-sensitivity.

Important Safety Information

Indication

NEXOBRID® (anacaulase-bcdb) is indicated for eschar removal in adults and pediatric patients with deep partial thickness (DPT) and/or full thickness (FT) thermal burns.

Limitations of Use

The safety and effectiveness of NEXOBRID have not been established for treatment of:

  • Chemical or electrical burns
  • Burns on the face, perineum, or genitalia
  • Burns on the feet of patients with diabetes mellitus or on the feet of patients with occlusive vascular disease
  • Circumferential burns
  • Burns in patients with significant cardiopulmonary disease, including inhalation injury

NEXOBRID is not recommended for:

  • Wounds contaminated with radioactive and other hazardous substances to avoid unforeseeable reactions with the product and an increased risk of spreading the noxious substance
  • Treatment of burn wounds where medical devices (e.g., implants, pacemakers, shunts) or vital structures (e.g., large vessels) could become exposed during eschar removal

Important Safety Information

Contraindications

NEXOBRID is contraindicated in patients with: known hypersensitivity to anacaulase-bcdb, bromelain, pineapples, or to any other components; known hypersensitivity to papayas or papain because of the risk of cross-sensitivity.

Warnings and Precautions

Hypersensitivity Reactions

Serious hypersensitivity reactions, including anaphylaxis, have been reported with postmarketing use of anacaulase-bcdb. If a hypersensitivity reaction occurs, remove NEXOBRID (if applicable) and initiate appropriate therapy.

Healthcare personnel should take appropriate precautions to avoid exposure when preparing and handling NEXOBRID (e.g., gloves, surgical masks, other protective coverings, as needed).

Coagulopathy

Avoid use of NEXOBRID in patients with uncontrolled disorders of coagulation. Use with caution in patients on anticoagulant therapy or other drugs affecting coagulation, and in patients with low platelet counts and increased risk of bleeding from other causes. Monitor patients for possible signs of coagulation abnormalities and signs of bleeding.

Adverse Reactions

The most common adverse reactions (>5%) in adults were pruritus, pyrexia, wound complication, anemia, vomiting and insomnia. The most common adverse reactions (>5%) in pediatric patients were pruritus, pyrexia and vomiting.

Use in Special Populations
Geriatric Use

Clinical studies of NEXOBRID did not include sufficient numbers of subjects 65 years of age and older to determine whether they respond differently from younger adult subjects.

To report negative side effects contact Vericel Corporation at 888-454-BURN (888-454-2876) or FDA at 1-800-FDA-1088 (1-800-332-1088) or www.fda.gov/medwatch.

Please see Full Prescribing Information.